Mahindra INDUSTRIAL ENGINES
In ProductionMahindra 4905 GMA-C2
Powerol
Mahindra 4905 GMA-C2 3.532L 4-cylinder diesel engine for generator sets. 62.5 kVA standby / 50 kWe at 50Hz. Indian CPCB market. Naturally Aspirated.
Standby Power
63 kVA
Electrical Output
50 kWe
Cylinders / Config
L4
Displacement
3.532 L
Rated Speed
1,500 RPM
ISO 8528 Power Ratings
Power Factor: 0.8 pfkWm = mechanical engine shaft power · kWe = electrical output · kVA = apparent electrical power.
| Operating Duty | kWm (Mechanical) | kWe (Electrical) | kVA (Rating) |
|---|---|---|---|
| Prime | 50 | 45 | 56.3 |
| Standby | 55.6 | 50 | 62.5 |
Mechanical & Electrical Specifications
| Brand | Mahindra |
| Model | 4905 GMA-C2 |
| Series | Powerol |
| Configuration | L4 |
| Cylinders | 4 |
| Displacement | 3.532 L |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Unregulated |
| Country of Origin | India |
Frequently Asked Questions
What is the power output of the Mahindra 4905 GMA-C2?
The Mahindra 4905 GMA-C2 is rated at 63 kVA standby / 56 kVA prime at 50 Hz (1,500 rpm).
Does the 4905 GMA-C2 run at 50 Hz or 60 Hz?
The Mahindra 4905 GMA-C2 is rated for 50 Hz (1,500 rpm).
What fuel does the Mahindra 4905 GMA-C2 use?
The Mahindra 4905 GMA-C2 is a diesel generator-set engine.
What is the displacement and cylinder configuration of the 4905 GMA-C2?
The Mahindra 4905 GMA-C2 is an inline-4 (4-cylinder) engine with a displacement of 3.532 L.
Is the Mahindra 4905 GMA-C2 still in production?
Yes — the Mahindra 4905 GMA-C2 is a current production model.
Is a datasheet available for the 4905 GMA-C2?
Yes — an official Mahindra datasheet for the Mahindra 4905 GMA-C2 can be downloaded from this page.