MWM INDUSTRIAL ENGINES
In ProductionMWM TCG 3016 V08
TCG 3016
MWM TCG 3016 V08 — 17.5 L V8 spark-ignition gas engine (TCG 3016 series), multi-fuel: natural gas, biogas and sewage/landfill gas. 400 kWe at 1500 rpm / 50 Hz, 400 kWe at 1800 rpm / 60 Hz; NOx ≤ 500 mg/Nm³.
Standby Power
500 kVA
Electrical Output
400 kWe
Cylinders / Config
V8
Displacement
17.5 L
Rated Speed
1,500 RPM
ISO 8528 Power Ratings
Power Factor: 0.8 pfkWm = mechanical engine shaft power · kWe = electrical output · kVA = apparent electrical power.
| Operating Duty | kWm (Mechanical) | kWe (Electrical) | kVA (Rating) |
|---|---|---|---|
| Prime | — | 400 | 500 |
| Operating Duty | kWm (Mechanical) | kWe (Electrical) | kVA (Rating) |
|---|---|---|---|
| Prime | — | 400 | 500 |
Mechanical & Electrical Specifications
| Brand | MWM |
| Model | TCG 3016 V08 |
| Series | TCG 3016 |
| Configuration | V8 |
| Cylinders | 8 |
| Displacement | 17.5 L |
| Dry Weight | 5720 kg |
| Dimensions (L×W×H) | 3100 × 1780 × 2150 mm |
| Fuel Type | Natural Gas |
| Ignition Type | Spark Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Unregulated |
| Country of Origin | Germany |
Frequently Asked Questions
What is the power output of the MWM TCG 3016 V08?
The MWM TCG 3016 V08 is rated at 500 kVA prime at 50 Hz (1,500 rpm); and 500 kVA prime at 60 Hz (1,800 rpm).
Does the TCG 3016 V08 run at 50 Hz or 60 Hz?
The MWM TCG 3016 V08 is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).
What fuel does the MWM TCG 3016 V08 use?
The MWM TCG 3016 V08 is a Natural Gas generator-set engine.
What is the displacement and cylinder configuration of the TCG 3016 V08?
The MWM TCG 3016 V08 is a V8 (8-cylinder) engine with a displacement of 17.5 L.
Is the MWM TCG 3016 V08 still in production?
Yes — the MWM TCG 3016 V08 is a current production model.
Is a datasheet available for the TCG 3016 V08?
Yes — an official MWM datasheet for the MWM TCG 3016 V08 can be downloaded from this page.