PSI INDUSTRIAL ENGINES
In ProductionPSI 17L
PSI 17L is a 16.7 L V8 spark-ignition natural-gas generator engine. Natural-gas ratings: 50 Hz prime 275 kWe / 320 kWm; 50 Hz standby 275 kWe / 320 kWm; 60 Hz prime 350 kWe / 420 kWm; 60 Hz standby 400 kWe / 460 kWm. Ratings exclude propane/LPG data and were verified from official PSI natural-gas rating tables.
Standby Power
500 kVA
Electrical Output
400 kWe
Cylinders / Config
V8
Displacement
16.7 L
Rated Speed
1,500 RPM
ISO 8528 Power Ratings
Power Factor: 0.8 pfkWm = mechanical engine shaft power · kWe = electrical output · kVA = apparent electrical power.
| Operating Duty | kWm (Mechanical) | kWe (Electrical) | kVA (Rating) |
|---|---|---|---|
| Prime | 320 | 275 | 343.8 |
| Standby | 320 | 275 | 343.8 |
| Operating Duty | kWm (Mechanical) | kWe (Electrical) | kVA (Rating) |
|---|---|---|---|
| Prime | 420 | 350 | 437.5 |
| Standby | 460 | 400 | 500 |
Mechanical & Electrical Specifications
| Brand | PSI |
| Model | 17L |
| Configuration | V8 |
| Cylinders | 8 |
| Displacement | 16.7 L |
| Fuel Type | Natural Gas |
| Ignition Type | Spark Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | U.S. EPA Stationary |
| Certifications | EPA |
| Country of Origin | United States |
Frequently Asked Questions
What is the power output of the PSI 17L?
The PSI 17L is rated at 344 kVA standby / 344 kVA prime at 50 Hz (1,500 rpm); and 500 kVA standby / 438 kVA prime at 60 Hz (1,800 rpm).
Does the 17L run at 50 Hz or 60 Hz?
The PSI 17L is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).
What fuel does the PSI 17L use?
The PSI 17L is a Natural Gas generator-set engine.
What is the displacement and cylinder configuration of the 17L?
The PSI 17L is a V8 (8-cylinder) engine with a displacement of 16.7 L.
What emissions standard does the 17L meet?
The PSI 17L is certified to U.S. EPA Stationary emissions standards.
Is the PSI 17L still in production?
Yes — the PSI 17L is a current production model.
Is a datasheet available for the 17L?
Yes — an official PSI datasheet for the PSI 17L can be downloaded from this page.